Call or Text: 713-465-0202

Charging And Gauging

We offer an extensive selection of charging and gauging equipment for our accumulators.  We are also able to help charge your in-field accumulators through our network of distributors or with our on-site service and repair program.  Please contact us for a quote on charging equipment or to set up a service appointment.

CHARGING AND GAUGING KITS FOR 3000 PSI ACCUMULATORS

3000 PSI Charging Kits
Kit with 3000 PSI Gauge (Items 1a-11)AI-CG3-3KT-SS
Kit with 6000 PSI Gauge (Items 1b-11) AI-CG3-6KT-SS

WARNING!

AI-CG3-3KT-SS and AI-CG3-6KT-SS are rated to 3000 PSI maximum working pressure. Connects to a maximum 3000 PSI nitrogen tank with a CGA 580 connection.

Do not use on accumulators with a pressure higher than 3000 PSI. It is highly recommended that a N2 gas regulator be used while charging any accumulator. Use dry nitrogen gas (N2) only.

ALSO AVAILABLE:

  • Complete accumulator repair kits
  • N2 gas regulators
  • Special order C&G kits with different connections and different hose lengths
Component Parts List
PARTDESCRIPTIONPART NUMBER
1a3000 PSI GaugeAI-CG3-001
1b6000 PSI GaugeAI-CG6-001
2Air ChuckAI-CG-002
3Adapter BlockAI-CG-003
4Swivel ConnectorAI-CG-004
5Tank ValveAI-CG-005
6CouplerAI-CG-006
7Hose (8 ft.)AI-CG-007-SS
8Gland (Nipple) AI-CG-008
9Bleed ValveAI-CG-009
10NutAI-CG-011
11Copper WasherAI-CG-020
Gauging & Head Assembly, 3000 PSI Gauge (Items 1a-5, 9, 11)AI-CG3-013
Gauging & Head Assembly, 6000 PSI Gauge (Items 1b-5,9,11)AI-CG6-013
Hose Assembly (items 6,7,8, 10)AI-CG-017-SS
Valve Core (internal) AI-S-304

CHARGING AND GAUGING KITS FOR 4000, 5000 & 6000 PSI ACCUMULATORS

Full Assembly Component Parts List
PARTDESCRIPTIONPART NUMBER
Complete Kit (Items 1-8)AI-CG6-6KT-SS
1Gauge, 6000 PSIAI-CG6-501-SS
2Air Chuck AI-CG6-502-SS
3CrossAI-CG6-503-SS
4JIC AdapterAI-CG6-506-SS
5Hose (8 ft.)AI-CG6-507-SS
6Cylinder Valve TubeAI-CG6-508-SS
7Bleed ValveAI-CG6-509-SS
8Cylinder Valve NutAI-CG6-511-SS
Hose Assembly (Items 2, 5)AI-CG6-517-SS
Gauging & Head Assembly (Items 1, 3, 4, 6, 7, 8)AI-CG6-613-SS

WARNING!

AI-CG6-6KT-SS is rated to 6000 PSI maximum working pressure. Do not use on accumulators with a pressure higher than 6000 PSI. Connects to a maximum 6000 PSI nitrogen tank with a CGA 677 connection. It is highly recommended that a N2 gas regulator be used while charging any accumulator. Use dry nitrogen gas (N2) only.

ALSO AVAILABLE:

  • Complete accumulator repair kits
  • N2 gas regulators
  • Special order C&G kits with different
    connections and different hose lengths

10000 PSI CHARGING AND GAUGING ASSEMBLY

Component Parts List
PARTDESCRIPTIONPART NUMBER
10K C&G Assembly (Items 1-8)AI-CG10-10KT-SS
1Gauge (0-10000 PSI, liquid filled)AI-CG10-001-L-SS
2Block FittingAI-ADP-A-NPT4M-MH6M-15-SS
3Adapter BlockAI-CG10-503-SS
4Bleed ValveAI-CG10-509-SS
5Needle ValveAI-CG10-510-SS
6Hose (4ft)AI-CG10-507-4-R
7Air Chuck AdapterAI-ADP-A-NPT2F-MH6M-15-SS
8Air ChuckAI-CG10-502-SS

WARNING!

AI-CG10-10KT-SS is rated to 10000 PSI maximum working pressure. Do not use on accumulators with a pressure higher than 10000 PSI. It is highly recommended that a N2 gas regulator be used while charging any accumulator. Use dry nitrogen gas (N2) only.

ALSO AVAILABLE:

  • Complete accumulator repair kits
  • N2 gas regulators
  • Special order C&G kits with different connections and different hose lengths

Extended versions available for Top Repairable bladder accumulators and piston accumulators.

3000 AND 6000 PSI DELUXE PERMANENT MOUNT PRESSURE MONITORS

3000 PSI

AI-PM3-3KT-L-SS Components List 1 - 40 GAL
PARTDESCRIPTIONPART NUMBER
1Protective CapAI-306-4-SS
2Valve CapAI-S-303
3Gas ValveAI-GT3-309-SS
4O-RingAI-GT3-311
5Pressure Monitor Block, Deluxe, 3000 PSIAI-PM3-003-D-SS
6Gauge, 3000 PSI, Liquid FilledAI-CG3-001-1-L-SS

6000 PSI

AI-PM6-6KT-L-SS Components List 1 QT - 15 GAL
PARTDESCRIPTIONPART NUMBER
1Protective CapAI-306-2-SS
2Valve CapAI-S-303
3High Pressure Gas ValveAI-S6-309
4O-RingAI-S6-310
5Pressure Monitor Block, Deluxe, 6000 PSIAI-PM6-003-D-SS
6Gauge, 6000 PSI, Liquid FilledAI-CG6-001-1-L-SS

3000 AND 6000 PSI BASIC PERMANENT MOUNT PRESSURE MONITORS

  • These units are intended to be mounted permanently on the valve stem of the accumulator to monitor hydraulic system pressure. Nitrogen precharge may only be measured when hydraulic line pressure is zero PSI.
  • We recommend the use of a liquid-filled gauge for high-cycle shock applications.
  • Accumulator gas valve must be removed prior to installation. Ensure all accumulator pressure has been removed before beginning installation.
  • Custom and digital assemblies are available

We recommend a nitrogen regulator to anyone precharging an accumulator. The regulator ensures that nitrogen is added to your accumulator at a safe rate, which protects the bladder from damage as well as keeps the air temperature inside your accumulator from rising during compression. Use of a nitrogen regulator is an essential safety factor.

We stock several different types of nitrogen regulators compatible with our accumulators. Please contact us for more information.

Our nitrogen gas boosters are designed to boost directly from high pressure storage cylinders to outlet pressures of up to 10000 psi. The unit ensures maximum outlet pressure fills even if the supply storage pressure drops as low as 500 psi.

The booster operates from a low-pressure, conventional compressed air source or “bootstraps,” directly from the high-pressure nitrogen supply. In the shop-air drive mode, non-contaminated outlet gas is assured through complete dual-vented separation from the drive section.

The high-pressure section of the booster is cooled by the drive exhaust gas and requires no lubrication. Valves and gauges are SS line-mounted to the booster. All items are mounted on a painted, aluminum tubular frame with carry handles.

CONTROLS INCLUDED

  • Single acting double drive gas booster configuration.
  • Automatic control to stop/restart the booster when the outlet pressure exceeds set point; pre-selected pressure up to 6000 psi (adjustable, depending on model).
  • Manual start and stop
  • High pressure air controls (HP regulator, relief valve, inlet & regulated outlet gauges and on/off valve)
  • Adjustable safety relief valve
  • Gas inlet and outlet gauges

SPECIFICATIONS

  • Dimensions: 30”L x 12”D x 12”H
  • Weight: 60 pounds
  • Maximum outlet pressure: 6000, 7500, or 10000 psi

For assistance determining the appropriate accumulator size for your application, please contact us.